Skip to the main content.
Icon

Who We Are

Fire protection professionals committed to safeguarding lives, property, and peace of mind.

Icon

Industries

Solutions designed for your property type, from multi-family housing to healthcare facilities to retail spaces.

Icon

 

Monitoring Services

Fire alarm, area of refuge, camera, and card access monitoring services.

Icon

Fire Alarm Systems

Clear communication and instant response when every second counts.

Icon

Fire Suppression Systems

From kitchens to server rooms, the right protection for every space.

Icon

Fire Sprinkler Systems

Keep your primary defense system ready and reliable.

Icon

 

Access Control

Manage all your properties' access from one simple platform.

Icon

Security Cameras

Monitor multiple properties in real time from anywhere, at any time.

Icon

 

Budget and Planning Scheduler

Document upcoming maintenance appointments and improve your proactive budget planning.

Icon

Fire Extinguisher Maintenance Checklist

Learn the requirements for testing extinguishers monthly, annually, and beyond.

Icon

 

Inspection Scheduler

Track all your inspection deadlines in one place.

Icon

Kitchen Hood Inspection Checklist

Ensure your kitchen hoods are safe and compliant. Download a complete list of testing requirements.

Icon

 

Guide to Fire & Security Monitoring

Your complete property protection handbook in practical terms.

Icon

 

Food Truck Compliance Guide

Running a food truck takes work—this guide gives you the tools to keep it safe and up to code.

Icon

Comprehensive Guide to NFPA 13 and NFPA 25 Fire Sprinkler Systems

Navigate sprinkler system requirements with confidence using our straightforward guide to codes and maintenance.

Icon

 

Fire Protection Checklist

Get your essential compliance guide.

Icon

Case Study: North Star Dining

When reliability matters across 18 restaurants, micromanagement doesn't.

5 min read

NFPA Standards for Food Trucks: Rules, Regulations, and Systems

NFPA Standards for Food Trucks: Rules, Regulations, and Systems

Key Takeaways

If you run a food truck, three fire safety rules matter most: keeping your hood and ventilation system clean (NFPA 96), having the right fire extinguishers on hand (NFPA 10), and maintaining the automatic fire suppression system above your cooking equipment (NFPA 17A).

Fire safety is critical for food truck owners. The National Fire Protection Association (NFPA) provides over 300 standards, but only a handful directly impact mobile food operations. 

Know which standards apply to your truck — it can help you stay compliant, pass inspections, and avoid costly shutdowns or equipment damage.

For food truck operators, three NFPA standards matter most:

  • NFPA 96: Kitchen ventilation and suppression systems (your hood system)
  • NFPA 10: Portable fire extinguishers (what you keep accessible in your truck)
  • NFPA 17A: Wet chemical extinguishing systems (the suppression system that protects your cooking equipment)

These standards translate directly into inspection requirements, insurance compliance, and daily operational safety.

Key NFPA Standards

Fire protection in a food truck isn't complicated—but it does require attention to specific details. NFPA standards give you clear guidelines on what systems you need, how to maintain them, and how often to inspect them.

Here’s an overview of the standards for mobile food operations.

NFPA 10: Portable Fire Extinguishers

NFPA 10 guides the selection and maintenance of hand-held fire extinguishers for immediate response to limited fires. In a food truck, this means keeping the right type of extinguisher accessible and ensuring it's inspection-ready at all times.

Different types of fire require different suppression: 

  • Class A fires involve wood, textiles, or paper 
  • Class B fires involve flammable liquids
  • Class C fires are electrical
  • Class K fires involve cooking oils and fats (the most common fire risk in food trucks)

Fire extinguishers should be visually inspected monthly for physical damage and charge levels. Check that the pressure gauge is in the green zone, the pin and tamper seal are intact, and there's no visible damage to the hose or nozzle. Your inspector will look for current inspection tags during health and fire safety inspections. 

Periodic hydrostatic testing is also required, depending on the extinguisher type. For Class K extinguishers, this typically means testing every five years. Keep records of all inspections and maintenance; inspectors may ask to see them.

NFPA 17A: Wet Chemical Extinguishing Systems

NFPA 17A specifically covers wet chemical suppression systems—the automatic fire suppression installed in your hood system above fryers, grills, and other cooking equipment. This is the system that deploys when temperatures get dangerously high, releasing a potassium-based agent that: 

  • Cools the fire
  • Creates a barrier between the fuel (cooking oil) and oxygen
  • Prevents re-ignition

What NFPA 17A requires:

  • Semiannual inspections (every six months) by a certified technician
  • Professional servicing if the system has been activated or if any component shows wear
  • Documentation of all inspections and maintenance

If your suppression system isn't up to code, inspectors can shut you down. Insurance may deny claims if maintenance records aren't current. And in a grease fire, a malfunctioning system means the fire spreads, potentially destroying your truck and putting people at risk.

Between professional inspections, visually check:

  • Nozzles and caps for blockages or damage
  • Fusible links (the heat-sensitive triggers) for grease buildup
  • Pull station accessibility (make sure your manual activation isn't blocked)

NFPA 96: Ventilation Control and Fire Protection of Commercial Cooking Operations

NFPA 96 is the comprehensive standard governing kitchen ventilation systems—which, in a food truck, means your hood, ductwork, exhaust fan, and the suppression system integrated within it. This standard ensures that grease, smoke, and heat are properly removed from your cooking area, reducing fire risk and maintaining air quality.

What NFPA 96 requires:

  • Proper hood design and installation (sized correctly for your cooking equipment and positioned at the right height)
  • Access panels in ductwork for cleaning and inspection
  • Regular hood and duct cleaning to prevent grease buildup (frequency depends on cooking volume—typically quarterly to semiannually for high-volume trucks)
  • Grease filters that are cleaned or replaced regularly
  • Fire suppression system integration with your cooking equipment (when you turn off the fuel or power, the suppression system should also shut down the exhaust fan)

Grease buildup in your ventilation system is one of the leading causes of food truck fires. If grease ignites in the ductwork, it can spread rapidly and be difficult to extinguish. Regular cleaning prevents this risk and keeps your truck in compliance during inspections.

Between professional cleanings:

  • Wipe down hood surfaces daily
  • Clean or replace grease filters weekly (or more often if you're cooking high-volume greasy foods)
  • Check for grease drips or buildup around seams

How Inspectors Use NFPA Standards to Evaluate Food Trucks

When fire marshals, health inspectors, or event coordinators review your food truck, they're checking whether your setup meets NFPA guidelines. Here's what they're looking for:

Hood and Suppression System (NFPA 96 and 17A):

  • Current inspection tags (are your semiannual suppression inspections up to date?)
  • Clean hoods and filters (is grease buildup minimal?)
  • Proper clearances (is your hood positioned correctly over cooking equipment?)
  • Accessible manual pull station (can you quickly activate suppression if needed?)

Fire Extinguishers (NFPA 10):

  • Proper mounting and accessibility (are extinguishers within reach and unobstructed?)
  • Current inspection tags (monthly checks documented?)
  • Correct extinguisher types (Class K near cooking, ABC for general use)
  • Good condition (no visible damage, pressure in the green zone)

Fuel Storage and Ventilation (NFPA 96):

  • Propane tank placement (stored outside the truck, away from heat sources)
  • Ductwork integrity (no holes, proper sealing, access panels present)

Documentation:

  • Maintenance records for suppression systems
  • Cleaning logs for hood and ductwork
  • Extinguisher inspection records

If any of these items are out of compliance, inspectors can issue citations or fines, require immediate corrections before you can operate, revoke permits for events or locations, or flag your truck for follow-up inspections.

Staying ahead of inspections means keeping your systems maintained and your records organized.

Fire Safety Confidence and Peace of Mind

While NFPA standards are comprehensive, they can feel complex, especially when you're managing frequently updated regulations. Each food truck has unique requirements, making professional guidance essential. If you’re looking for assistance in servicing your mobile kitchen, our experts at Brothers Fire & Security can help.

Frequently Asked Questions

How often do I need to have my hood suppression system inspected?

NFPA 17A requires semiannual inspections (every six months) by a certified technician. Mark your calendar and keep inspection tags visible—inspectors will check them.

What happens if my suppression system goes off accidentally?

Once activated, your system must be professionally serviced before you can operate again. The chemical agent needs to be recharged, and all components must be inspected for proper function. Don't attempt to reset it yourself.

Can I clean my own hood and ductwork, or do I need a professional?

You should clean filters and accessible hood surfaces regularly (weekly for high-volume operations). However, deep cleaning of ductwork should be done by a professional certified in hood cleaning to ensure grease is fully removed and access panels are properly resealed.

Do I need both a Class K and an ABC extinguisher?

If you have a kitchen hood system, the answer is Yes. A Class K extinguisher handles grease fires near cooking equipment. An ABC extinguisher covers other fire types (wood, paper, electrical, flammable liquids) elsewhere in your truck. Both should be easily accessible.

How are NFPA requirements different for food trucks compared to restaurant kitchens?

Food trucks almost always use wet chemical hood suppression systems (NFPA 17A) rather than water-based sprinklers, since space and water supply are limited. Your ventilation system is more compact with shorter duct runs, and you'll use portable propane tanks instead of fixed gas lines. Fire alarm systems (NFPA 72) are rarely required in food trucks due to the small size and open layout, but suppression system maintenance is even more critical because fire risks are concentrated in a tighter space.

How do I know if my food truck meets NFPA standards?

Review your suppression system inspection tags, check your extinguisher maintenance records, and ensure your hood is clean with no excessive grease buildup. If you're unsure, schedule an evaluation with a fire protection professional before your next inspection.

What if my truck was built before current NFPA standards were updated?

Older trucks may be "grandfathered" under previous codes, but this varies by jurisdiction. Some municipalities require retrofits to meet current standards. Check with your local fire marshal or health department to understand what's required in your area.

Making the Switch: Vendor Transition Guide

Making the Switch: Vendor Transition Guide

Switching fire and security vendors feels risky. Even if your current provider isn't meeting your needs, the thought of transitioning systems and...

Continue reading this post →
What to Do When Your Security Vendor Goes Silent

What to Do When Your Security Vendor Goes Silent

Your fire alarm shows a trouble signal. Last week's sprinkler inspection never happened, and despite three calls and multiple messages, your vendor...

Continue reading this post →