Skip to the main content.
Icon

Who We Are

Fire protection professionals committed to safeguarding lives, property, and peace of mind.

Icon

Industries

Solutions designed for your property type, from multi-family housing to healthcare facilities to retail spaces.

Icon

 

Monitoring Services

Fire alarm, area of refuge, camera, and card access monitoring services.

Icon

Fire Alarm Systems

Clear communication and instant response when every second counts.

Icon

Fire Suppression Systems

From kitchens to server rooms, the right protection for every space.

Icon

Fire Sprinkler Systems

Keep your primary defense system ready and reliable.

Icon

 

Access Control

Manage all your properties' access from one simple platform.

Icon

Security Cameras

Monitor multiple properties in real time from anywhere, at any time.

Icon

Intrusion Detection

Secure your property with real-time unauthorized access alerts.

Icon

 

Budget and Planning Scheduler

Document upcoming maintenance appointments and improve your proactive budget planning.

Icon

Fire Extinguisher Maintenance Checklist

Learn the requirements for testing extinguishers monthly, annually, and beyond.

Icon

 

Inspection Scheduler

Track all your inspection deadlines in one place.

Icon

Kitchen Hood Inspection Checklist

Ensure your kitchen hoods are safe and compliant. Download a complete list of testing requirements.

Icon

 

Guide to Fire & Security Monitoring

Your complete property protection handbook in practical terms.

Icon

 

Food Truck Compliance Guide

Running a food truck takes work—this guide gives you the tools to keep it safe and up to code.

Icon

Comprehensive Guide to NFPA 13 and NFPA 25 Fire Sprinkler Systems

Navigate sprinkler system requirements with confidence using our straightforward guide to codes and maintenance.

Icon

 

Fire Protection Checklist

Get your essential compliance guide.

Icon

Case Study: North Star Dining

When reliability matters across 18 restaurants, micromanagement doesn't.

Icon

 

Guide to Multi-Location Security

Questions to ask when evaluating access control.

Icon

Case Study: Two Food Trucks, One Standard for Safety

For food truck operators, fire safety compliance is a responsibility that never parks.

2 min read

Minnesota Building Code: Sprinkler Requirements Explained

Minnesota Building Code: Sprinkler Requirements Explained

Fire sprinkler provisions have been in building codes for decades. Automatic fire sprinkler systems greatly improve survival rates and decrease the risk of financial loss by limiting the spread of flames. A well-designed automatic sprinkler system is critical to the overall safety of a residential building.

A common misconception among designers and property owners is that the NFPA 13 Standard for the Installation of Sprinkler Systems determines which buildings must have automatic sprinkler systems.

Actually, NFPA 13 identifies the criteria for these fire suppression systems. A state’s building code identifies when they’re required.

In Minnesota, the state building code establishes the requirements for automatic sprinkler systems in residential buildings. That said, it’s important to review the requirements from all applicable codes in your jurisdiction when determining the minimum fire safety requirements in a building. A good rule of thumb is to adhere to whichever code is more restrictive.

Where Fire Sprinkler Systems Are Code Required

Here's a breakdown of which residential building types trigger the requirement:

  • Townhouses with 3 or more units: Each unit counts as its own building and needs its own sprinkler system. Attached garages need a dry head sprinkler. Attached combustible patios or decks over 40 square feet need a dry head sprinkler for every 20 linear feet of shared wall, or interior sprinklers that act as a water curtain.

  • Multiunit resort buildings: Required if the resort has sleeping accommodations near a lake, stream, or recreational area like a ski hill or hunting grounds, and the building exceeds 9,250 square feet.

  • Bed and breakfasts: Required with 6 or more guest rooms.

  • Boarding houses (transient and non-transient): Required for more than 10 occupants.

  • Congregate living facilities (transient and non-transient): Required for more than 16 occupants.

  • Hotels and motels: Required.

  • Apartment buildings: Required.

  • Convents, monasteries, dormitories, fraternities, sororities, and timeshares: Required if the building exceeds 4,500 square feet.

  • Care facilities over 4,500 square feet: Required. This includes child and adult day care centers, supervised living facilities, residential hospice facilities, adult and child foster care homes, senior housing facilities and nursing homes, and assisted living facilities.

The only buildings exempt from having fire sprinkler systems are those containing one or two separate single-family dwelling units (however, a separate licensing agency may require them).

Monitoring Fire Protection and Life Safety Systems

Fire protection system monitoring is just as important as the systems themselves. Timely detection is key to saving lives and preventing costly property damage and injuries.

While the entire system is required to be thoroughly inspected, tested, and maintained annually (once per year with a minimum of 9 months, maximum 15 months), some components need to be tested semiannually (twice per year with a minimum of 4 months, maximum of 8 months) by an approved servicing company in accordance with Chapter 14 of NFPA 72 (see Tables 14.3.1 and 14.4.5).

Work with fire alarm monitoring professionals to ensure your fire protection and life safety systems are up to code and working as they should.

Fire alarm monitoring helps ensure that no alarms go unheard. To find out more about sprinkler requirements or discuss monitoring services for fire systems, call us at 763-441-2290 or visit our contact us page.

Frequently Asked Questions

No. Single-family homes with one or two dwelling units are generally exempt, though a separate licensing agency may still require them. Everything else depends on building type, size, and occupancy.

Minnesota's building code sets that requirement, not NFPA 13. NFPA 13 covers how a system should be designed and installed once the code determines one is required.

Your local fire marshal or building official can confirm the current requirements for your address, including any city-specific amendments. It is also recommended to check with your insurance carrier to see what they will require.

Existing systems generally need to meet the code in place when they were installed, though some older buildings, like certain high-rises, face newer retrofit deadlines.

At minimum, once a year. Some components or insurance agencies require more frequent testing such as semiannual testing, and full performance tests occur on a 3- to 5-year cycle, depending on the system type.

Key Takeaways

  • Minnesota's building code, not NFPA 13, decides which properties need automatic sprinklers. 

  • Requirements depend on building type, size, and occupancy, so confirm specifics with your local fire marshal. 

  • Fire Sprinklers reduce injury and property loss across residential, hospitality, and care settings.